INSTRUMENTS AVAILABLE IN PHARMACOLOGY AND TOXICOLOGY LAB
|
Name of Instrument |
Maker (Model No.) |
|
Hot Plate Analgesiometer
Specifications Ø Footswitch to start, stop and ready the instrument. Ø Temperature sensor is located in the centre of the black anodized plate. Ø Keypad, allow all parameters to be entered for the test |
IITC Life science (39)
Application
Used to measure the analgesic activity of Rodents
|
|
Electronic Randall Selitto test system
Ø Footswitch are provided to for operating the instruments. Ø Pressure applicaator |
IITC Life science (2500)
Application
To measure the pain threshold
|
|
Digital Plethysmometer Specifications
Ø Footswitch are provided to for operating the instruments. Ø Acrylic stand with Electronic unit to measure the volume
|
IITC Life science (2500)
Application
To measure the effectiveness of anti-inflammatory agents to reduce edema conditions digitally on both mice and rat
|
|
Microprobe Digital Thermometer
Specifications
Ø BAT-12 reads to-100°C to +200°C with 0.1 resolutions. Ø Super Accuracy and Fast Readings Ø Auto Corrected for Ambient Temperature
|
Physitemp instrument INC Model (BAT-12)
Application
For measuring the temperature
|
|
Rotamix-5 Specifications Ø Number of Exercise Lanes: 4 Ø Rotarod Spindle Speed Range: 0 - 99.9 RPM Ø Acceleration Increments: 0.1 RPM per second. to 20.0 RPM per second Ø Mouse Spindle Dimensions: 3.0 cm x 9.5 cm
Ø Rat Spindle Dimensions: 7.0 cm x 9.5 cm Ø Fall height From Rod center: 44.5 cm Ø Unit Dimensions(LxWxH): 61cm X 56cm X 77cm Ø Animal Detection Method: Scanning infrared beam(32) sensors monitor animals absence from rod assembly. Ø Communication (optional): RS-232 to RS422(CIBUS) Multi drop. (Max of 64 devices) |
Columbus Instruments (0254-2002L)
Application
Muscle relaxant activity of rodents
|
|
PACS-30
Specifications
Ø Performs both Active and Passive Avoidance Testing Ø Supports operation of up to 30 boxes Ø Standard visual and acoustical stimuli Ø Avoidance Cage Dimensions: 19"L x 9"W x 10.75"H (48cm x 23cm x 27cm) Ø Motion Detection Method: Multiple Infrared Beams
|
Columbus Instruments
Application
Used for Active and passive avoidance behavior
|
|
Opto-Varimex-4
Specifications
Ø Number of beam light are 4 to 6, depending on the sensor size and type Ø Beam diameter is 0.0125 inches and beam length is 875 nm. Ø Control unit 35 cm*29 cm* 10 cm
|
Columbus Instruments
Application
Activity of drugs on rodents |
|
Digital stereo taxis
Specifications
Ø EZ clips,Non sterile, Box/200 Ø EZ clip applier Ø EZ remover Ø Dermo moto tool Ø The large LED display is also useful for surgeries performed in low light, or constrained environments where reading the vernier scale is difficult.
|
Stoelting (51500D)
Application
It is used to perform surgeries on both mice and rat with greater speed and accuracy due to the digital display
|
|
Sociability Apparatus
Specifications
Ø Main enclosures divided in to 3 components. Ø Width, depth and height is 60 cm*40cm*22cm Ø Connected to Any Maze video tracking software.
|
Stoelting (60450)
Application
It is used to perform autistic-like behaviors in rodents
|
|
Open field
Specifications
Ø The open field arena had semi-transparent (frosted) Perspex walls, with an internal diameter of 40 x 40 cm. Ø Connected to Any Maze video tracking software.
|
Stoelting (60100)
Application
The Open Field is broadly used to assess exploratory behavior, and is validated for use in the measurement of anxiety-related Behaviors.
|
|
T maze for Mouse and Rat
Specifications
Ø Walls fit solidly in slotted base, but lift off for easy cleaning. Ø base plate is grey and non reflective Ø Connected to Any Maze video tracking software.
|
Stoelting (60181,60281)
Application
It is used largely in preference and spatial learning tasks.
|
|
Elevated Plus maze for rat and mouse
Specifications
Ø Lane width,Arm length, Wall height, Leg height are 10*50*40*40cm for Rat and 5cm*35*15*40cm for Mouse. Ø Walls fit solidly in slotted base, but lift off for easy cleaning. Ø base plate is grey and non reflective Ø Connected to Any Maze video tracking software.
|
Stoelting (60140,60240)
Application
It is used to assess anxiety-like behavior in Rodent. The maze exploits the conflict between the innate fear that rodents have of Open areas versus their desire to explore novel environments.
|
|
TSE Animal Respirator Compact
Specifications
Ø The individual adjustment of ventilation parameters like as breathing frequency, inspiration length, plateau length - and pressure parameters such as EIP value (end-inspiratory pressure), EIP Limit (maximal trachea pressure during inspiration), etc. is possible
|
TSE system
Application
It is used for the respiration of small laboratory animals such as mice and young rats
|
|
Rodent shocker
Specifications
Ø Stimulation Frequency 50 Hz or 60 Hz according to supply frequency Ø Stimulus Duration 0.1 sec to 9.9 sec in steps of 0.1 sec, selected after Ø pressing a button, the selected time is indicated Ø Constant current, fully floating Output Current 0 to 300 mA, 0 to 150 mA, 0 to 100 mA Ø Limitation of Maximum 250 V, 500 V, 750 V in 3 steps, selected by button |
HSE Haverd instrument (Type 221)
Application
Testing the anticonvulsant drug on mice and rat by using eye and ear electrode
|
|
Radnoti Lagendorff system
Specifications
Ø Stand Assembly Ø Water jacket heart chamber with a collecting trap perfusate manifolds and valves Ø Water jacket reservoir with aerators and peristaltic and thermal circulator pump Ø Power Lab 26 T and software |
AD Instruments (PTK28-220)
Application
It is used the examination of cardiac contractile strength and heart rate without the complications of an intact animal.
|
|
8 Channel Organ bath with Power Lab
Specifications
Ø Automatic filling and emptying of organ bath tube using controller knobs on control panel Ø Compact and robust design Ø Precise control over bubbling speed from control panel Ø Maintenance Free- Use of Teflon stopcock based system in place of solenoid valve Ø Available with analogue and digital temperature controller Ø No leakage- Thick perspex single joint tank Ø No glass parts- Organ bath tube is made of P. P. And reservoir coil is made of perspex making system breakage free and maintenance free Ø Uniform Temperature- Inbuilt water circulation pump for uniform temperature control
|
Orchid Scientific (PTK28-220)
Application
In vitro response of drug in Isolated tissue. |
|
Power Lab 26T with Bridge AMP
|
AD Instruments, Australia
Application
Recording the Blood pressure, ECG and HRV (Diastolic, Systolic, pulse pressure) |
|
Digital Balance
Specifications
Ø Capacity 220 grams Ø Display Backlit Display Ø Overall Height 331 mm Ø Overall Length 290 mm Ø Overall Width 193 mm Ø Readout Accuracy 0.0001 grams Ø Size 220g Capacity
|
Mettler-Toledo (ML204/A01)
Application
Weighing the chemical |
|
Optical Upright Microscope
Specifications
Ø Binocular Research Microscope Ø Anti fungus optics and High performance aspheric lenses Ø SMPS circuit Illumination System Ø Parfocality & precentred objectives |
Olympus (CH 20i)
Application
Used for microscopic study |
|
Gel Electrophoresis unit (vertical and horrizontal setup) and Blotting Assembly
Specifications
Ø Sub- cell R GT Agarose gel electrophoresis Ø Mini proteinR Tetra cell Ø Trans-BlotR SD Semi-Dry Electrophoretic Transfer Cell |
Bio-Rad
Application
Use for electrophoresis and transfer of DNA,RNA and protein
|
|
UV Transilluminator
Specifications
Ø Sub- cell R GT Agarose gel electrophoresis Ø Mini proteinR Tetra cell Ø Trans-BlotR SD Semi-Dry Electrophoretic Transfer Cell |
Ge NeiTM (107171)
Application
Use for visuliading the DNA
|
|
Multiscan FC
Specifications
Ø Plate Type 96-well plates Ø Light Source Quartz-halogen lamp Ø Detector Type Photodetector Ø Wavelength Selection Filters Ø Wavelength Range 340 to 850nm Ø Filters 8-position filter wheel; filters installed was 405 nm,450 nm,492 nm,550nm,620nm,690nm
|
Thermofisher Scintific
Application
Immunoassays (ELISA), protein assays, endotoxins, cytotoxicity and proliferation assay
|
|
CO2 Incubator
Ø Temperature range from 4°C above ambient to 50°C. Ø Sealed, inner glass door allows observation of samples without disturbing cultures. Ø RS-232 and 25mm access ports for use with external instruments. Ø IR sensor comes standard for specific and accurate control of CO2 levels. IR sensor comes standard for specific and accurate control of CO2 levels. |
Eppendorf (C017EM601895)
Use for cell culture and bacteria incubation |
|
Veriti® 96-Well Thermal Cycler
Ø Temperature Range: 4.0-99.9 °C. Ø Ramp Rate: Max Block Ramp Rate 3.9 °C⁄Sec, Max Sample Ramp Rate 3.35 °C⁄Sec Ø Tm Calculator Ø Temperature Uniformity: <0.5 °C (20 sec after reaching 95 °C) |
Applied Biosystem (2990225536)
amplification of specific DNA fragments by the polymerase chain reaction (PCR) |
|
|
|
|
|
|
|
Deep freezer (-20°C)
|
Mehrotra Biotech
|
|
Spinix vortex shaker Specifications
|
Tarsons
Application
Use for vortexing |
|
Digital Wheel type swimming appratus
|
Techno Application
Use for the study of depression |
|
Cook's Pole climbing appratus
|
Techno Application
Use for the study of depression |
|
Audiogenic test chanber
|
Techno Application
Use to provides auditory stimulus for evaluation of ataraxic agents |
|
Histamine aerosol apparatus
|
Techno Application
Use for evaluation of Antihistaminic drug |
|
Parafin dispenser, Slide warming table and tissue floating bath
|
Nexgen
Application
Use for histology experiment
|
|
Microtome
Specifications
Ø Imaginative Knife Holder Adjustment Ø Safety During Sectioning
|
Yorco
Application
Use for cutting the section the tissue |